FDA UDI
In Commercial Distribution
🇺🇸 United States
H-V Lumbar Valve System
DI: 10381780035367
·
Model: 903325A
·
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
1
Basic Information
- Brand Name
- H-V Lumbar Valve System
- Primary DI
- 10381780035367
- Version / Model
- 903325A
- Catalog Number
- 903325A
- Company Name
- INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
- Labeler DUNS
- 531408342
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2015-10-01
- Public Version
- 4
- Public Version Date
- 2021-04-07
- Public Version Status
- Update
- Public Device Record Key
- 757660bc-29dc-4d72-ae92-70982787cdb9
Device Description
The Horizontal-Vertical Lumbar Valve System is an implantable device that provides controlled intraventricular pressure and cerebrospinal fluid (CSF) drainage from the lumbar subarachnoid region to the peritoneal cavity. The system minimizes overdrainage by automatically compensating for changes in CSF hydrostatic pressure when the patient changes from a recumbent to an upright position. Available in different closing pressure ranges (according horizontal and vertical orientations).
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- Yes
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- Yes
- MRI Safety
- MR Conditional
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| JXG | Shunt, central nervous system and components | Neurology | 882.5550 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 61523 | Lumboperitoneal shunt | An implantable device intended to divert excessive cerebrospinal fluid (CSF) from the subarachnoid space of the lumbar spine to the peritoneal cavity where it can be absorbed into the body, as a treatment for raised CSF pressure (e.g., caused by hydrocephalus). It consists of fully-implantable interconnected components: a spinal catheter implanted into subarachnoid space of the lumbar spine; a mechanical shunt valve that may incorporate a puncturable port/reservoir for sampling/infusion; a peritoneal catheter implanted into the peritoneal cavity; some types incorporate a subcutaneous anchor for component connection/positioning. Disposable devices associated with implantation may be included. | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 10381780035367 | GS1 | ||||
| Secondary | M272903325A1 | HIBCC |
Customer Contacts
- Phone
- +1(800)654-2873
- [email protected]
Premarket Submissions
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Device Size Text, specify | Closing Pressure Range (BLUE) Horizontal: 85-125mmH2O / Vertical: 205-285mmH2O, Distal Cath. 91cm Length x 2.3mm O.D. x 1.1mm I.D. (F7), Lumb. Cath. 80cm Length x 1.6mm O.D. x 0.8mm I.D. (F5) |