FDA UDI
Not in Commercial Distribution
🇺🇸 United States
Pilling
DI: 10190776027145
·
Model: P18655
·
Avalign Technologies, Inc.
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
2
Basic Information
- Brand Name
- Pilling
- Primary DI
- 10190776027145
- Version / Model
- P18655
- Company Name
- Avalign Technologies, Inc.
- Labeler DUNS
- 792528510
- Distribution Status
- Not in Commercial Distribution
- Device Count in Pkg
- 2
- Record Status
- Published
- Publish Date
- 2017-03-23
- Public Version
- 5
- Public Version Date
- 2023-11-22
- Public Version Status
- Update
- Public Device Record Key
- 06611133-4ae2-4d8c-affe-6f3eaa57039d
- Distribution End Date
- 2023-11-21
Device Description
Single Clamp, Hand Applied, pair
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| DXC | CLAMP, VASCULAR | Cardiovascular | 870.4450 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 35798 | Open-surgery ligation clip applier | A hand-held manual surgical instrument designed to apply small atraumatic clips (not included) for the ligation of blood vessels, or similar tubular anatomy, mainly to prevent and/or stop bleeding (i.e., haemostasis) during an open-surgery procedure. It may also be used to apply small clamps (e.g., bulldog type) to tissues however it is not intended to apply an aneurysm clip. The device is typically a metallic instrument with flat, curved ends to hold and deliver the clips (e.g., forceps-like); implantable clips are not included. This is a reusable device after sterilization. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 10190776027145 | GS1 | ||||
| Unit of Use | 00190776027148 | GS1 |
Customer Contacts
- Phone
- +1(877)289-1096
- [email protected]
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Width | 3.5 | Millimeter | |
| Width | 1.5 | Millimeter |