FDA UDI
In Commercial Distribution
🇺🇸 United States
AVEA
DI: 10190752174801
·
Model: 68339K
·
VYAIRE MEDICAL, INC.
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- AVEA
- Primary DI
- 10190752174801
- Version / Model
- 68339K
- Catalog Number
- 68339K
- Company Name
- VYAIRE MEDICAL, INC.
- Labeler DUNS
- 080456871
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2021-05-07
- Public Version
- 1
- Public Version Date
- 2021-05-17
- Public Version Status
- New
- Public Device Record Key
- f5ebb250-0222-4d17-8fef-66d4416b7d06
Device Description
BATTERY ASSEMBLY, 24V, 4.5AH, NIMH, AVEA
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- No
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| CBK | Ventilator, continuous, facility use | Anesthesiology | 868.5895 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 38489 | Uninterruptible power supply | A portable device, commonly known as an uninterruptible power supply (UPS), designed to provide a continuous supply of electrical power for a limited period of time to a connected device or devices during the failure of the mains electricity (AC-power) supply due to an emergency situation, e.g., a blackout, or maintenance/testing. It will contain its own set of batteries that normally maintain their charge from the mains power supply and it is these that provide the power when a failure in the line-power occurs. This device is used locally (at the point of use) and is often reserved to supply vital devices, e.g., ventilators, patient monitoring devices and computer dependent devices. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 10190752174801 | GS1 |
Customer Contacts
- Phone
- +1(833)327-3284
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K103211 | 000 |