Nucleus
DI: 09321502009522
·
Model: S50621
·
COCHLEAR LIMITED
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Nucleus
- Primary DI
- 09321502009522
- Version / Model
- S50621
- Catalog Number
- S50621
- Company Name
- COCHLEAR LIMITED
- Labeler DUNS
- 750551194
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2014-09-24
- Public Version
- 5
- Public Version Date
- 2022-04-08
- Public Version Status
- Update
- Public Device Record Key
- 85a21ccc-f5b3-4b3c-8f31-c27db51e54e7
Device Description
FREEDOM PROCESSING UNIT, BROWN
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- Yes
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| MCM | IMPLANT, COCHLEAR | Unknown | 3 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 47374 | Cochlear implant/auditory brainstem implant sound processor | An external component of a cochlear implant (CI) or auditory brainstem implant system that typically consists of a battery-powered microphone/transmitter (transducer) designed to convert sound waves from the environment into electrical signals which are transmitted to the implantable portion of the system, via a coil (which may or may not be included), for the partial restoration of auditory sensation in a severely/profoundly deaf person. Also known as a speech processor, it is typically worn like a behind-the-ear (BTE) or off-the-ear (OTE) hearing aid. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 09321502009522 | GS1 |
Customer Contacts
- Phone
- +1(800)523-5798
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| P970051 | 028 |
Storage Conditions
- Type
- Storage Environment Humidity
- Temperature Range
- 0 – 90 Percent (%) Relative Humidity
- Type
- Storage Environment Temperature
- Temperature Range
- -20 – 50 Degrees Celsius
- Type
- Handling Environment Humidity
- Temperature Range
- 0 – 90 Percent (%) Relative Humidity
- Type
- Handling Environment Temperature
- Temperature Range
- -20 – 50 Degrees Celsius