FDA UDI
In Commercial Distribution
🇺🇸 United States
Set of electrodes
DI: 09120073931948
·
Model: V1.0
·
CNSystems Medizintechnik GmbH
Product Codes
1
GMDN Terms
1
Identifiers
3
Pkg Device Count
1
Basic Information
- Brand Name
- Set of electrodes
- Primary DI
- 09120073931948
- Version / Model
- V1.0
- Catalog Number
- 1616
- Company Name
- CNSystems Medizintechnik GmbH
- Labeler DUNS
- 300526077
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2018-10-04
- Public Version
- 2
- Public Version Date
- 2023-12-18
- Public Version Status
- Update
- Public Device Record Key
- 97701745-3fac-4b81-84d7-0c85763fb994
Device Description
Set of 4ECG electrodes, 3 ICG electrodes and one grounding pad
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| DXN | System, Measurement, Blood-Pressure, Non-Invasive | Cardiovascular | 870.1130 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 61020 | Analytical non-scalp cutaneous electrode | An electrical conductor designed to be attached to the skin surface of a patient outside of the hair line (i.e., non-scalp) to conduct electrical signals to/from a parent device for electrophysiological recording/monitoring [e.g., electromyography (EMG), evoked potentials (EP), nerve conduction study (NCS), bioelectrical impedance]; it is not primarily intended for diagnostic electrocardiography (ECG) or electroencephalography (EEG). It typically consists of a small rectangular tab or cup/disk with a conductive surface, which may include a lead wire. This is a single-patient device that may be reapplied to the patient over a short term (single-use) before being discarded. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Package | 09120073931962 | GS1 | Box | 12 | In Commercial Distribution | |
| Package | 09120073931955 | GS1 | Box | 10 | In Commercial Distribution | |
| Primary | 09120073931948 | GS1 |
Customer Contacts
- Phone
- +4331672345633
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K014063 | 000 |
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- 0 – 40 Degrees Celsius
- Type
- Storage Environment Humidity
- Temperature Range
- 20 – 95 Percent (%) Relative Humidity
- Type
- Storage Environment Atmospheric Pressure
- Temperature Range
- 50 – 106 KiloPascal
- Type
- Handling Environment Temperature
- Temperature Range
- 10 – 40 Degrees Celsius
- Type
- Handling Environment Humidity
- Temperature Range
- 30 – 85 Percent (%) Relative Humidity
- Type
- Handling Environment Atmospheric Pressure
- Temperature Range
- 70 – 106 KiloPascal