FDA UDI
In Commercial Distribution
🇺🇸 United States
Niti-S Biliary Slim M Stent
DI: 08809744975290
·
Model: BN0609-6
·
TAEWOONGMEDICAL.CO.,LTD
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Let the assistant research this device
The Research Assistant compiles product codes, classification, clearances and adverse events for this device — and cites every record.
Free to try · every answer cites its records
Basic Information
- Brand Name
- Niti-S Biliary Slim M Stent
- Primary DI
- 08809744975290
- Version / Model
- BN0609-6
- Company Name
- TAEWOONGMEDICAL.CO.,LTD
- Labeler DUNS
- 689484322
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2022-06-22
- Public Version
- 3
- Public Version Date
- 2026-04-07
- Public Version Status
- Update
- Public Device Record Key
- 7a1a54d1-5a52-4cc1-a4f1-624a7eddb471
Device Description
Bare Metal Biliary Stent System
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- MR Conditional
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- Yes
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- Yes
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| FGE | Stents, Drains And Dilators For The Biliary Ducts | Gastroenterology, Urology | 876.5010 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 43691 | Bare-metal biliary stent | A non-bioabsorbable tubular device intended to be implanted in an obstructed biliary duct (e.g., common bile duct) to maintain luminal patency; it is not intended for vascular implantation. It may be a mesh structure or a continuous tube and is made entirely of metal [e.g., high-grade stainless steel, cobalt-chrome (Co-Cr), nickel-titanium alloy (Nitinol)]. It may be expandable in situ (e.g., with a balloon catheter or self-expands) and disposable devices intended to assist implantation may be included. | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 08809744975290 | GS1 |
Customer Contacts
- Phone
- 323-692-0028
- [email protected]
- Phone
- +82319960641
- [email protected]
Premarket Submissions
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Stent Diameter | 6 | Millimeter | |
| Stent Length | 90 | Millimeter | |
| Catheter Working Length | 180 | Centimeter | |
| Crossing Profile | 6 | French |