FDA UDI
In Commercial Distribution
🇺🇸 United States
HANAROSTENT LowAxTM Colon/Rectum(NNN)
DI: 08806367076243
·
Model: CNJF-22-090-140
·
M.I.Tech Co., Ltd.
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- HANAROSTENT LowAxTM Colon/Rectum(NNN)
- Primary DI
- 08806367076243
- Version / Model
- CNJF-22-090-140
- Company Name
- M.I.Tech Co., Ltd.
- Labeler DUNS
- 688454359
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2018-11-20
- Public Version
- 1
- Public Version Date
- 2018-12-21
- Public Version Status
- New
- Public Device Record Key
- 914c7a0e-84f1-4f72-a07d-065ea993051e
Device Description
Un-covered self-expanding nitinol Colon stent
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- MR Unsafe
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- Yes
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| MQR | Stent, Colonic, Metallic, Expandable | General, Plastic Surgery | 878.3610 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 37847 | Bare-metal colonic stent | A sterile non-bioabsorbable tubular device intended to be implanted in the lumen of the colon for the palliative treatment of colonic strictures caused by malignant neoplasms typically in the descending or sigmoid colon, or rectum. It is typically inserted and advanced to the site of implantation with a dedicated catheter, or other instrument, where it self-expands upon release. It is made of metal [e.g., stainless steel or metal alloy such as nickel-titanium alloy (Nitinol)] in a tubular mesh configuration, and is available in various sizes. It will typically be used to relieve large bowel obstruction prior to colectomy, or in patients having high operative risk and/or advanced disease. | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 08806367076243 | GS1 |
Customer Contacts
- Phone
- +827043047405
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K180180 | 000 |
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Length | 1400 | Millimeter | |
| Stent Length | 90 | Millimeter | |
| Stent Diameter | 22 | Millimeter |
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- 15 – 35 Degrees Celsius