FDA UDI
In Commercial Distribution
🇺🇸 United States
Bencox Hip System
DI: 08800017281599
·
Model: HA.08B.0012
·
Corentec Co., Ltd
Product Codes
3
GMDN Terms
2
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Bencox Hip System
- Primary DI
- 08800017281599
- Version / Model
- HA.08B.0012
- Company Name
- Corentec Co., Ltd
- Labeler DUNS
- 688739895
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2018-11-20
- Public Version
- 3
- Public Version Date
- 2022-06-10
- Public Version Status
- Update
- Public Device Record Key
- 456012d9-c0b6-416a-b701-16322c9e9a39
Device Description
Bencox M Stem RASP No.12 (Standard Offset)
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| LPH | Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented | Orthopedic | 888.3358 | 2 |
| KWY | Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented | Orthopedic | 888.3390 | 2 |
| LZO | Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented | Orthopedic | 888.3353 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 35559 | Bone file/rasp, manual, reusable | A hand-held manual surgical instrument with a surface(s) of coarse and/or fine grooves or teeth designed to scrape and smooth the surface of bone during a surgical procedure. The device is typically a one-piece instrument with grooves/teeth along all or part of its working end(s). It is available in a variety of sizes and working end designs, including straight and curved ends and often double-ended with a central handle. It is not dedicated for use at a specific anatomy (e.g., sinus, ear) and it is made of metal [e.g., stainless steel, titanium (Ti)]. This is a reusable device. | No | Active |
| 58481 | Femoral stem prosthesis trial | A copy of a final femoral stem prosthesis designed to be used for trial reductions during hip arthroplasty to judge the correct offset, leg-length, and range of motion of the final femoral prosthesis to be implanted. It is one of a set, or a set, of graduated sizes, and is used in conjunction with femoral head trial prostheses. It is typically made of metal or polymer material and includes trial stems, trial sleeves, and trial necks. This is a reusable device intended to be sterilized prior to use. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 08800017281599 | GS1 |
Customer Contacts
- Phone
- +820415857114
- [email protected]