FDA UDI
Not in Commercial Distribution
🇺🇸 United States
HI-TORQUE ADVANCE
DI: 08717648014499
·
Model: 1044589
·
ABBOTT VASCULAR INC.
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
1
Basic Information
- Brand Name
- HI-TORQUE ADVANCE
- Primary DI
- 08717648014499
- Version / Model
- 1044589
- Catalog Number
- 1044589
- Company Name
- ABBOTT VASCULAR INC.
- Labeler DUNS
- 964569052
- Distribution Status
- Not in Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-02-19
- Public Version
- 7
- Public Version Date
- 2023-12-11
- Public Version Status
- Update
- Public Device Record Key
- dc8d5046-460e-4f1a-b673-bfbb333ef579
- Distribution End Date
- 2023-12-10
Device Description
HI-TORQUE ADVANCE Guide Wire .014 Straight Tip 3.0 cm x 300 cm
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- Yes
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| DQX | WIRE, GUIDE, CATHETER | Cardiovascular | 870.1330 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 35094 | Cardiac/peripheral vascular guidewire, single-use | A long, thin, sterile wire intended to be percutaneously placed into the cardiac vasculature (ventricles or coronary vessels) to function as a guide for the introduction, positioning, and/or operation of a device (e.g., catheter, pacing lead); it may also be used in the peripheral vasculature. It may be made of metal (e.g., stainless steel, Nitinol), or polymer and/or glass materials to provide MRI-compatibility, with or without coating, and is available in a variety of distal tip designs. It is used for various diagnostic and interventional procedures, and may include devices used to facilitate manipulation (e.g., torque device). This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Package | 28717648014493 | GS1 | Case | 5 | Not in Commercial Distribution | 2023-12-10 |
| Primary | 08717648014499 | GS1 |
Customer Contacts
- Phone
- +1(800)227-9902
- [email protected]
Storage Conditions
- Type
- Special Storage Condition, Specify
- Special Conditions
- Stored in a dry, dark, cool place