FDA UDI
In Commercial Distribution
🇺🇸 United States
Habib™ EndoHPB
DI: 08714729981909
·
Model: M00500070
·
BOSTON SCIENTIFIC CORPORATION
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Habib™ EndoHPB
- Primary DI
- 08714729981909
- Version / Model
- M00500070
- Company Name
- BOSTON SCIENTIFIC CORPORATION
- Labeler DUNS
- 021717889
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2018-09-14
- Public Version
- 3
- Public Version Date
- 2019-04-23
- Public Version Status
- Update
- Public Device Record Key
- 2a253c53-bb12-4c47-b12a-db24c9239088
Device Description
Biopolar Radiofrequency Catheter
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| KNS | Unit, electrosurgical, endoscopic (with or without accessories) | Gastroenterology, Urology | 876.4300 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 57944 | Endoscopic electrosurgical handpiece/electrode, bipolar, single-use | A sterile electrosurgical device which consists of a handpiece with mechanical and/or electrical controls, and a bipolar electrode intended to deliver electrosurgical current from a system generator directly to tissues for cutting/coagulation/ablation during endoscopic (including laparoscopic, arthroscopic) surgery, and may in addition be intended for open surgery; it is not intended for focal percutaneous ablation. It includes a long thin electrode connected to the handpiece, and may include a lumen for suction/irrigation; it is available in a variety of forms (e.g., forceps, rigid probe with controls). This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 08714729981909 | GS1 |
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Catheter Gauge | 8 | French |