FDA UDI
Not in Commercial Distribution
🇺🇸 United States
SpyScope
DI: 08714729764434
·
Model: M00546230
·
BOSTON SCIENTIFIC CORPORATION
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- SpyScope
- Primary DI
- 08714729764434
- Version / Model
- M00546230
- Company Name
- BOSTON SCIENTIFIC CORPORATION
- Labeler DUNS
- 021717889
- Distribution Status
- Not in Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-09-24
- Public Version
- 4
- Public Version Date
- 2023-07-27
- Public Version Status
- Update
- Public Device Record Key
- 4921f999-1cf1-4bfe-b732-5bd1452b544e
- Distribution End Date
- 2020-01-03
Device Description
Access and Delivery Catheter
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| ODF | Mini endoscope, gastroenterology-urology | Gastroenterology, Urology | 876.1500 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 16429 | ERCP catheter, non-balloon, non-electrical, single-use | A non-electrical flexible tube inserted through a flexible endoscope, after its placement in the duodenum via the oral cavity, for the endoscopic cannulation of the gastrointestinal ductal system (i.e., the pancreatic, hepatic, and/or common bile ducts) during endoscopic retrograde cholangiopancreatography (ERCP). It is typically a single-lumen device made of radiopaque plastic materials with incremental markings at the distal tip, used to deliver a contrast medium to the ducts for their radiographic visualization; it does not incorporate a balloon. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 08714729764434 | GS1 |
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Device Size Text, specify | 4.2 mm Diameter | ||
| Device Size Text, specify | 250 cm Effective Length | ||
| Device Size Text, specify | 1.2 mm Diameter |