FDA UDI
In Commercial Distribution
🇺🇸 United States
FlowArt®
DI: 08699443580105
·
Model: AYWB7010TY
·
ASSET MEDIKAL TASARIM SANAYI VE TICARET ANONIM SIRKETI
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
1
Basic Information
- Brand Name
- FlowArt®
- Primary DI
- 08699443580105
- Version / Model
- AYWB7010TY
- Company Name
- ASSET MEDIKAL TASARIM SANAYI VE TICARET ANONIM SIRKETI
- Labeler DUNS
- 365581688
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2023-09-26
- Public Version
- 1
- Public Version Date
- 2023-10-04
- Public Version Status
- New
- Public Device Record Key
- 0ed21dfa-c89b-45ed-8a25-a07f0f229216
Device Description
Six Port Flexible Manifold w/One-way Split Septum Needle-Free Valves
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- Yes
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| FPA | Set, Administration, Intravascular | General Hospital | 880.5440 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 42743 | Negative-pressure intravenous line needleless valve-connector | A small, stand-alone, Luer-activated needleless plastic valve intended to mate two related intravenous (IV) line devices [e.g., hypodermic syringe and catheter port or tubing from an IV administration set] and hold them in a secured, sealed, locked position until disconnection, at which point negative pressure from the device causes a small volume of retrograde fluid flow into the catheter/tubing. It is intended to eliminate the use of needles for IV administration of medications. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Package | 28699443580109 | GS1 | Box | 50 | In Commercial Distribution | |
| Primary | 08699443580105 | GS1 |
Customer Contacts
- Phone
- +1(314) 961-5786
- [email protected]
- Phone
- +1(800) 969-6331
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K190806 | 000 |
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- – 40 Degrees Celsius