FDA UDI
In Commercial Distribution
🇺🇸 United States
Titanium Acetabular Screw
DI: 08052532831975
·
Model: Acetabular Screw
·
ADLER ORTHO SPA
Product Codes
4
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Titanium Acetabular Screw
- Primary DI
- 08052532831975
- Version / Model
- Acetabular Screw
- Catalog Number
- 0601040
- Company Name
- ADLER ORTHO SPA
- Labeler DUNS
- 338847291
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2025-03-04
- Public Version
- 1
- Public Version Date
- 2025-03-12
- Public Version Status
- New
- Public Device Record Key
- 8c1e6581-9fb5-4f42-9faf-2e09ab5672d2
Device Description
Titanium Acetabular Screw Diam. 6.5 mm L. 40 mm
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| LPH | Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented | Orthopedic | 888.3358 | 2 |
| JDI | Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented | Orthopedic | 888.3350 | 2 |
| LZO | Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented | Orthopedic | 888.3353 | 2 |
| MBL | Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Porous | Orthopedic | 888.3358 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 66947 | Orthopaedic bone screw (non-sliding) | A small, threaded, non-bioabsorbable, implantable rod intended for internal orthopaedic fixation by being screwed into a limb bone, rib, the sternum and/or pelvis to hold a plate, nail, rod or prosthesis to the bone, or to provide direct interfragmentary stabilization of a fractured bone; it is not intended to be introduced through the sleeve of a femoral neck fixation plate/sleeve, not used in dentistry/orthodontics, craniofacial or spinal bones, and not dedicated to intramedullary fixation/arthrodesis. It is typically of cortical or cancellous design and has a drive (e.g., slot, cross, star, polygonal) at its proximal end for introduction with a screwdriver. | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 08052532831975 | GS1 |
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Device Size Text, specify | Diam. 6.5mm, L. 40mm |