FDA UDI
Not in Commercial Distribution
🇺🇸 United States
FiberNet
DI: 08033477034300
·
Model: FBC600700190
·
MEDTRONIC, INC.
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- FiberNet
- Primary DI
- 08033477034300
- Version / Model
- FBC600700190
- Company Name
- MEDTRONIC, INC.
- Labeler DUNS
- 006261481
- Distribution Status
- Not in Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-05-08
- Public Version
- 4
- Public Version Date
- 2019-04-09
- Public Version Status
- Update
- Public Device Record Key
- 0281ac53-9cff-4246-864d-4082993a9e52
- Distribution End Date
- 2018-10-05
Device Description
Cath FBC600700190 FBC SW 6.0-7.0 UL1900
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| NTE | Temporary Carotid Catheter for Embolic Capture | Cardiovascular | 870.1250 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 44841 | Embolic protection filtering guidewire | A steerable wire with a filter at its distal end intended to be used to facilitate the placement of diagnostic/interventional vascular devices (e.g., angioplasty balloons, intravascular stents) in the lumen of a blood vessel (coronary, carotid, peripheral), and to provide embolic protection by capturing emboli that may result from the procedure. The filter is deployable (expandable) once inserted distal to the vascular lesion (e.g., atherosclerotic plaque). It typically includes devices for introduction/removal of the guidewire (e.g., deployment/removal sheath), which are not intended to be used as working channels for other interventional devices. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 08033477034300 | GS1 |
Customer Contacts
- Phone
- +1(800)633-8766
- [email protected]
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Device Size Text, specify | 6.0-7.0 MM Recommended Vessel Diameter | ||
| Length | 190.0 | Centimeter |
Storage Conditions
- Type
- Special Storage Condition, Specify
- Special Conditions
- Store at controlled room temperature, in a dry place. Keep away from sunlight.