FDA UDI
In Commercial Distribution
🇺🇸 United States
BMN I TYPE
DI: 08033003343487
·
Model: BMN I TYPE
·
H.S. HOSPITAL SERVICE SPA
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
1
Let the assistant research this device
The Research Assistant compiles product codes, classification, clearances and adverse events for this device — and cites every record.
Free to try · every answer cites its records
Basic Information
- Brand Name
- BMN I TYPE
- Primary DI
- 08033003343487
- Version / Model
- BMN I TYPE
- Catalog Number
- I 1408M
- Company Name
- H.S. HOSPITAL SERVICE SPA
- Labeler DUNS
- 428898555
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2019-12-18
- Public Version
- 1
- Public Version Date
- 2019-12-26
- Public Version Status
- New
- Public Device Record Key
- c746ac7e-2513-44b9-a605-04d8b2fa91fa
Device Description
BMN I TYPE 14GX19-30-63-80MM
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- Yes
- MRI Safety
- MR Unsafe
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| KNW | Instrument, Biopsy | Gastroenterology, Urology | 876.1075 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 46350 | Bone marrow biopsy needle, single-use | A sterile, sharp bevel-edged, hollow tubular metal instrument designed to obtain a specimen of bone marrow percutaneously. The device is typically available in a variety of large bores, and is sufficiently robust to penetrate bone (usually the hip bone or posterior iliac crest) with the force of pressure and twisting manually applied to its proximal handgrip. The resultant specimen is typically used for the pathological analysis of the source of blood cellular elements. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Package | 38033003343488 | GS1 | 10 | In Commercial Distribution | ||
| Primary | 08033003343487 | GS1 |
Customer Contacts
- Phone
- +39069201961
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K020987 | 000 |
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Needle Gauge | 14 | Gauge | |
| Length | 80 | Millimeter |