FDA UDI
In Commercial Distribution
🇺🇸 United States
Pedimax II - Pedicular Screw Spinal System
DI: 07899258623108
·
Model: Rod to Rod Clamp
·
GM DOS REIS INDUSTRIA E COMERCIO LTDA
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Pedimax II - Pedicular Screw Spinal System
- Primary DI
- 07899258623108
- Version / Model
- Rod to Rod Clamp
- Catalog Number
- 134-228
- Company Name
- GM DOS REIS INDUSTRIA E COMERCIO LTDA
- Labeler DUNS
- 900865213
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2024-01-17
- Public Version
- 1
- Public Version Date
- 2024-01-25
- Public Version Status
- New
- Public Device Record Key
- a7dc0583-0323-41ad-bd27-65ab4201358f
Device Description
ROD TO ROD CLAMP Ø3,5 / 6,0mm LEFT
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- MR Conditional
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| NKB | Thoracolumbosacral Pedicle Screw System | Orthopedic | 888.3070 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 61325 | Bone-screw internal spinal fixation system, non-sterile | An assembly of non-sterile implantable devices intended to provide immobilization and stabilization of spinal segments in the treatment of various spinal instabilities or deformities, also used as an adjunct to spinal fusion [e.g., for degenerative disc disease (DDD)]. Otherwise known as a pedicle screw instrumentation system, it typically consists of a combination of anchors (e.g., bolts, hooks, pedicle screws or other types), interconnection mechanisms (incorporating nuts, screws, sleeves, or bolts), longitudinal members (e.g., plates, rods, plate/rod combinations), and/or transverse connectors. Non-sterile disposable devices associated with implantation may be included. | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 07899258623108 | GS1 |
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K180626 | 000 |