FDA UDI
In Commercial Distribution
🇺🇸 United States
imtmedical
DI: 07640149389005
·
Model: 301.470.020
·
IMTMEDICAL PTE. LTD.
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
1
Basic Information
- Brand Name
- imtmedical
- Primary DI
- 07640149389005
- Version / Model
- 301.470.020
- Catalog Number
- 301.470.020
- Company Name
- IMTMEDICAL PTE. LTD.
- Labeler DUNS
- 595438617
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2022-11-28
- Public Version
- 3
- Public Version Date
- 2023-10-18
- Public Version Status
- Update
- Public Device Record Key
- f31225d7-503f-41db-a5e3-5639b65da060
Device Description
iFlow 40 S Neonatal/Infant Proximal Flow Sensor
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- Yes
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| CBK | Ventilator, Continuous, Facility Use | Anesthesiology | 868.5895 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 61834 | Breathing circuit gas-sampling/monitoring set | A collection of non-sterile devices intended to be integrated within a breathing circuit to enable interface of gases between the breathing circuit and a respiratory monitoring device for sampling the patient's expired gas for measurements of pressure, flow and/or gas analysis [e.g., end-tidal carbon dioxide (EtCO2) concentration]. It includes both a tube/mask breathing circuit connector with sampling ports (sometimes referred to as a spirometry sensor) and gas-sampling/monitoring respiratory tubing; no electronic devices are included. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Package | 07640149388992 | GS1 | Case | 10 | In Commercial Distribution | |
| Primary | 07640149389005 | GS1 |
Customer Contacts
- Phone
- 1(833)327-3284
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K183364 | 000 |
Storage Conditions
- Type
- Storage Environment Humidity
- Temperature Range
- 10 – 90 Percent (%) Relative Humidity
- Type
- Storage Environment Temperature
- Temperature Range
- -20 – 50 Degrees Celsius
- Type
- Special Storage Condition, Specify
- Special Conditions
- Keep away from sunlight
- Type
- Special Storage Condition, Specify
- Special Conditions
- Keep Dry