FDA UDI
In Commercial Distribution
🇺🇸 United States
NA
DI: 07630031729583
·
Model: Digital impression
·
Institut Straumann AG
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Let the assistant research this device
The Research Assistant compiles product codes, classification, clearances and adverse events for this device — and cites every record.
Free to try · every answer cites its records
Basic Information
- Brand Name
- NA
- Primary DI
- 07630031729583
- Version / Model
- Digital impression
- Catalog Number
- 032.041
- Company Name
- Institut Straumann AG
- Labeler DUNS
- 483599259
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2022-12-02
- Public Version
- 3
- Public Version Date
- 2025-02-06
- Public Version Status
- Update
- Public Device Record Key
- 23ec70e3-4eac-44dc-bbca-59d7f0bff301
Device Description
CARES® CI RD Mono Scanbody, Ø 4.1mm, H 9mm, PEEK/Ti
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- Yes
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| NDP | Accessories, implant, dental, endosseous | Dental | 872.3980 | 1 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 61641 | Dental implant abutment analog, intraoral-scanning, single-use | An intraoral device intended to be used as a temporary copy of a dental implant abutment for attachment to a final dental implant and/or implant abutment during a scanning procedure to confirm its orientation/position as part of a dental restoration; it may in addition be intended for laboratory scanning. It is typically made of a radiopaque material (e.g., barium sulfate) and may be used in conjunction with an intraoral x-ray sensor. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 07630031729583 | GS1 |
Customer Contacts
- Phone
- +1(800)448-8168
- [email protected]
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Outer Diameter | 4.1 | Millimeter | |
| Height | 9 | Millimeter |
Storage Conditions
- Type
- Special Storage Condition, Specify
- Special Conditions
- Keep away from sunlight