FDA UDI In Commercial Distribution 🇺🇸 United States

ARGUS PB-3000

DI: 07613365004359 · Model: PB-3000 Var.10, sub-variant: M/I · Schiller AG
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1

Basic Information

Brand Name
ARGUS PB-3000
Primary DI
07613365004359
Version / Model
PB-3000 Var.10, sub-variant: M/I
Catalog Number
3.921033
Company Name
Schiller AG
Labeler DUNS
480868538
Distribution Status
In Commercial Distribution
Device Count in Pkg
1
Record Status
Published
Publish Date
2025-08-19
Public Version
2
Public Version Date
2026-01-09
Public Version Status
Update
Public Device Record Key
fd67a693-acf5-4f79-a4e7-e966aa8f260f

Device Description

"The ARGUS PB-3000 is a vital data acquisition unit intended to be used within or connected to a medical device or a medical System (Host System) for acquiring, analysing, and transmission of patient vitals and other pertinent clinical data of following vital date of a patient: ECG and Respiration ECG, heart rate, asystole time, respiration rate and apnoea time for monitoring and diagnostic purpose. IBP The IBP measurement is intended for continuously invasive measurement of a patient’s arterial and/or venous blood pressure in different locations. NIBP The NIBP measurement is intended for non-invasive measure blood pressure with different cuffs in different locations. SpO2 The SpO2 measurement is intended for non-invasive measuring of a patient’s oxygen saturation level and other parameters (e.g. SpCO, SpMet). CO2 and Respiration The CO2 measurement is intended for the non-invasive monitoring of a patient’s in and exhaled carbon dioxide, anaesthesia gases and to provide a respiration rate. Cardiac Output (CO) The Cardiac Output measurement is intended for measuring continuously blood and injected fluid temperature for calculating the current Cardiac Output of a patient in the medical system (Host System). Temperature The Temperature measurement is intended for non-invasive and invasive measurement of a patient’s temperature in different locations."

Device Characteristics

Single Use
No
Prescription Use (Rx)
Yes
Over the Counter (OTC)
No
Kit
No
Combination Product
No
HCT/P
No
Contains NRL
No
Not Made with NRL
No
MRI Safety
MR Unsafe
Direct Marking Exempt
No
PM Exempt
No
Has Serial Number
Yes
Has Lot/Batch Number
No
Has Manufacturing Date
Yes
Has Expiration Date
No
Has Donation ID
No

Sterilization

Is Sterile
No
Sterilization Prior Use
No

Product Codes

Code Name
MHX Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms)

GMDN Terms

Code Name
36553 Patient monitoring system module, multifunction

Identifiers

Type ID
Primary 07613365004359

Customer Contacts

Phone
+41417664242

Premarket Submissions

Submission Number Supplement Number
K221056 000

Storage Conditions

Type
Handling Environment Temperature
Temperature Range
-10 – 50 Degrees Celsius
Type
Storage Environment Temperature
Temperature Range
5 – 50 Degrees Celsius
Type
Handling Environment Humidity
Temperature Range
10 – 95 Percent (%) Relative Humidity
Type
Handling Environment Atmospheric Pressure
Temperature Range
50 – 106 KiloPascal