FDA UDI
In Commercial Distribution
🇺🇸 United States
IH-Card Control
DI: 07611969952212
·
Model: 813600100
·
Bio-Rad Medical Diagnostics GmbH
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Let the assistant research this device
The Research Assistant compiles product codes, classification, clearances and adverse events for this device — and cites every record.
Free to try · every answer cites its records
Basic Information
- Brand Name
- IH-Card Control
- Primary DI
- 07611969952212
- Version / Model
- 813600100
- Catalog Number
- 813600100
- Company Name
- Bio-Rad Medical Diagnostics GmbH
- Labeler DUNS
- 312576506
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2017-01-20
- Public Version
- 3
- Public Version Date
- 2018-07-06
- Public Version Status
- Update
- Public Device Record Key
- e481c569-ff3b-4d7f-bc47-b119c692542f
Device Description
Optional card for the negative control in ABO and Rh typing; 12 cards of 6 microtubes
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| KSF | Kit, Quality Control For Blood Banking Reagents | Hematology | 864.9650 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 52705 | Antisera matrix (non-reactive) IVD, control | A material consisting of antisera matrix but containing no active immunoglobulins that is intended be used as a negative control to verify the performance of an assay when testing a clinical specimen for red blood cell antigens. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 07611969952212 | GS1 |
Customer Contacts
- Phone
- 800-224-6723
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| BK140139 | 0 |
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- 18 – 25 Degrees Celsius