DI: 07540195050051
·
Model: 01FCO115D
·
O-Two Medical Technologies Inc
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- O-Two
- Primary DI
- 07540195050051
- Version / Model
- 01FCO115D
- Company Name
- O-Two Medical Technologies Inc
- Labeler DUNS
- 206449154
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2023-11-07
- Public Version
- 1
- Public Version Date
- 2023-11-15
- Public Version Status
- New
- Public Device Record Key
- 7b479e47-aaf2-41d9-9e57-e0edbc7e5db7
Device Description
The O-Two Adjustable Oxygen Therapy Flow Controller is a calibrated, 12-position, fixed orifice, non-gravity sensitive flow controller. T
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- Yes
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| CCN | Flowmeter, Nonback-Pressure Compensated, Bourdon Gauge | Anesthesiology | 868.2300 | 1 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 61366 | Medical gas flowmeter, dial-type | A device intended to regulate the flow of a medical gas [e.g., oxygen (O2), carbon dioxide (CO2), nitrous oxide (N2O), helium/oxygen gas mixture (heliox), medical air] during various procedures (e.g., therapeutic administration, anaesthesia, insufflation during surgery). It has a pre-calibrated adjustable flow selection dial intended to control the gas flow rate; it is not intended to provide flow rate measurements. It will be calibrated to a specific medical gas and have a dedicated flow rate range, therefore some types may be dedicated to a specific patient group (e.g., neonate, infant, adult) or clinical use. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 07540195050051 | GS1 |
Customer Contacts
- Phone
- (905) 792-6896
- [email protected]