FDA UDI
In Commercial Distribution
🇺🇸 United States
PF 6840-2 TC Remote Panel 2 Channels
DI: 07332834000806
·
Model: PF 6840-2
·
Perimed AB
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- PF 6840-2 TC Remote Panel 2 Channels
- Primary DI
- 07332834000806
- Version / Model
- PF 6840-2
- Company Name
- Perimed AB
- Labeler DUNS
- 354765570
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2023-02-01
- Public Version
- 1
- Public Version Date
- 2023-02-09
- Public Version Status
- New
- Public Device Record Key
- 640eebba-4e53-4aac-8f08-80f4a1e1b07a
Device Description
PF 6840-2 TC Remote Panel 2 Channels
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- Yes
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| LPP | Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia | Anesthesiology | 868.2500 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 46934 | Transcutaneous blood gas monitoring system | An assembly of mains electricity (AC-powered) devices designed for the continuous and transcutaneous measurement of a patient's blood gas parameters, typically blood partial pressure of oxygen (pO2), blood partial pressure of carbon dioxide (pCO2), haemoglobin oxygen saturation (SpO2), and/or venous blood oxygenation through the jugular vein (SjvO2); often with pulse rate. It consists primarily of a probe for gas detection (e.g., via transcutaneous gas diffusion, or using light spectroscopy) placed on the patient’s skin, and an oximetry monitor for the measurement, analysis, and display of data; patient adhesives and connecting cables may be included. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 07332834000806 | GS1 |
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K131253 | 000 |