FDA UDI
In Commercial Distribution
🇺🇸 United States
Provox Flush
DI: 07331791005930
·
Model: 8109
·
Atos Medical AB
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Provox Flush
- Primary DI
- 07331791005930
- Version / Model
- 8109
- Catalog Number
- 8109
- Company Name
- Atos Medical AB
- Labeler DUNS
- 355470923
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2022-07-12
- Public Version
- 1
- Public Version Date
- 2022-07-20
- Public Version Status
- New
- Public Device Record Key
- efda058a-5123-4dc4-9b9a-efdbaae802b0
Device Description
Provox Flush is intended to be used to flush drinking water or air through the inner lumen of a Provox voice prosthesis for cleaning purposes. The Flush is intended for both home and clinical use by patient or clinician. Single patient re-use.
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- No
- Over the Counter (OTC)
- Yes
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- MR Safe
- Direct Marking Exempt
- No
- PM Exempt
- Yes
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| LRC | Instrument, Ent Manual Surgical | Ear, Nose, Throat | 874.4420 | 1 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 62096 | Tracheoesophageal speech valve irrigation device | A non-sterile hand-held device intended to be used for the in situ washing of an indwelling tracheoesophageal speech valve by water irrigation to remove organic matter (e.g., phlegm). It is in the form of a water-fillable squeeze bulb with a distal nozzle that is inserted through the tracheostoma into the central lumen of the valve; it is intended to be used routinely by a patient in the home. This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 07331791005930 | GS1 |
Customer Contacts
- Phone
- +4641519800
- [email protected]
Storage Conditions
- Type
- Special Storage Condition, Specify
- Special Conditions
- Keep dry. Keep away from sunlight.
- Type
- Storage Environment Temperature
- Temperature Range
- 2 – 42 Degrees Celsius
- Type
- Storage Environment Temperature
- Temperature Range
- 36 – 108 Degrees Fahrenheit