FDA UDI
In Commercial Distribution
🇺🇸 United States
Provox NID 20, 6 mm
DI: 07331791000331
·
Model: 7111
·
Atos Medical AB
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Let the assistant research this device
The Research Assistant compiles product codes, classification, clearances and adverse events for this device — and cites every record.
Free to try · every answer cites its records
Basic Information
- Brand Name
- Provox NID 20, 6 mm
- Primary DI
- 07331791000331
- Version / Model
- 7111
- Catalog Number
- 7111
- Company Name
- Atos Medical AB
- Labeler DUNS
- 355470923
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-09-11
- Public Version
- 6
- Public Version Date
- 2024-11-25
- Public Version Status
- Update
- Public Device Record Key
- 018b2323-4538-44a5-80e9-97dc4281f7ba
Device Description
Provox NID is a non-indwelling voice prosthesis for patients who are capable of handling the exchange and maintenance of a voice prosthesis independently of a clinician or physician.
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- Yes
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| EWL | Prosthesis, Laryngeal (Taub) | Ear, Nose, Throat | 874.3730 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 44412 | Tracheoesophageal speech valve, non-indwelling | A non-sterile device designed to be inserted into a surgically-created tracheo-oesophageal fistula after total laryngectomy, following wound healing, to provide the patient with voice restoration. It is placed by the trained patient into the fistula. It has a double flange (one on the outside of the throat and one on the inside) to hold it in place and includes a one-way valve that protects the airway during swallowing and opens under positive pressure so that air crosses into the oesophagus to produce voice (speech rehabilitation). The user removes this device periodically for cleaning. This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 07331791000331 | GS1 |
Customer Contacts
- Phone
- +4641519800
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K043138 | 000 |
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Length | 6 | Millimeter |
Storage Conditions
- Type
- Special Storage Condition, Specify
- Special Conditions
- Keep away from rain. Keep away from sunlight.
- Type
- Storage Environment Temperature
- Temperature Range
- 36 – 108 Degrees Fahrenheit
- Type
- Storage Environment Temperature
- Temperature Range
- 2 – 42 Degrees Celsius