FDA UDI
In Commercial Distribution
🇺🇸 United States
Vivo 50, VIvo 65
DI: 07321820049103
·
Model: 004910
·
Breas Medical AB
Product Codes
2
GMDN Terms
1
Identifiers
2
Pkg Device Count
10
Basic Information
- Brand Name
- Vivo 50, VIvo 65
- Primary DI
- 07321820049103
- Version / Model
- 004910
- Catalog Number
- 004910
- Company Name
- Breas Medical AB
- Labeler DUNS
- 357007657
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 10
- Record Status
- Published
- Publish Date
- 2022-06-18
- Public Version
- 2
- Public Version Date
- 2022-12-26
- Public Version Status
- Update
- Public Device Record Key
- c5a3449f-48d7-4e5c-996b-4934cf2d1ae0
Device Description
Patient Air Inlet filter (white, disposable), 10 pcs
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| CBK | Ventilator, Continuous, Facility Use | Anesthesiology | 868.5895 | 2 |
| NOU | Continuous, Ventilator, Home Use | Anesthesiology | 868.5895 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 47083 | Portable electric ventilator | A portable, electrically-powered device intended to provide long-term alveolar support for patients who do not require complex critical care ventilation. It typically uses positive pressure to deliver gas to the lungs at normal breathing rates and tidal volumes through invasive ventilation (i.e., with an artificial airway); it may also be used non-invasively (e.g., with a mask). It includes a control system and alarms, and may include a built-in humidifier. Several methods of cycling and ventilation modes may be used. It may be line and/or internal/external battery-powered for use in the home or a healthcare facility (including ambulatory). | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Unit of Use | 07321820046683 | GS1 | ||||
| Primary | 07321820049103 | GS1 |
Customer Contacts
- Phone
- 855-436-8724
- [email protected]