FDA UDI
In Commercial Distribution
🇺🇸 United States
Distractor for Open Procedure
DI: 07290115935486
·
Model: 87625
·
PREMIA SPINE LTD
Product Codes
3
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Distractor for Open Procedure
- Primary DI
- 07290115935486
- Version / Model
- 87625
- Company Name
- PREMIA SPINE LTD
- Labeler DUNS
- 649220779
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2024-10-01
- Public Version
- 1
- Public Version Date
- 2024-10-09
- Public Version Status
- New
- Public Device Record Key
- a452121f-6a60-4e45-a252-775be5331743
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| NKB | Thoracolumbosacral Pedicle Screw System | Orthopedic | 888.3070 | 2 |
| MNI | Orthosis, Spinal Pedicle Fixation | Orthopedic | 888.3070 | 2 |
| MNH | Orthosis, Spondylolisthesis Spinal Fixation | Orthopedic | 888.3070 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 56637 | Orthopaedic surgical distractor, internal | A hand-held manual surgical instrument designed to invasively distract (force apart) two bone surfaces to enable a surgical procedure. It typically aids in fracture reduction by helping to temporarily stabilize bones prior to definitive surgical fixation. It typically consists of a central threaded spindle, a static endpiece and a sliding carriage that can be adjusted using spindle nuts to/from the endpiece to widen or shorten the gap; it facilitates the attachment of orthopaedic bone pins (Schanz screws) screwed into the bones to be distracted. It is typically used for multiple injuries when it is advantageous to perform procedures on a standard operating table. This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 07290115935486 | GS1 |