FDA UDI In Commercial Distribution 🇺🇸 United States

nordicBrainEx

DI: 07090042059015 · Model: 2.3 · Nordicneurolab AS
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1

Basic Information

Brand Name
nordicBrainEx
Primary DI
07090042059015
Version / Model
2.3
Company Name
Nordicneurolab AS
Labeler DUNS
671280238
Distribution Status
In Commercial Distribution
Device Count in Pkg
1
Record Status
Published
Publish Date
2017-05-07
Public Version
6
Public Version Date
2023-03-17
Public Version Status
Update
Public Device Record Key
f8e150a1-cba1-4c91-a088-5f20eae203e2

Device Description

The nordicBrainEx Software is a post-processing application for dynamic MRI data developed with focus on ease of use and high performance on a standard Windows workstation. The software provides comprehensive functionality for dynamic image analysis and visualization of MRI data, where signal changes over time are analyzed to determine various modality dependent functional parameters. The following algorithms provide the main functional analyses of the application. - BOLD: BOLD fMRI analysis is used to highlight small magnetic susceptibility changes in the human brain in areas with altered blood-flow resulting from neuronal activity. - DTI: Diffusion analysis is used to visualize local water diffusion properties from the analysis of diffusion-weighted MRI data. Fiber tracking utilizes the directional dependency of the diffusion to display the white matter structure in the brain. - DSC: Calculations of perfusion related parameters that provide information about the blood vessel structure and characteristics. Examples of such maps are blood volume, blood flow, time to peak, mean transit time and leakage. In addition to these specific functional analyses, the application also provides general visualization tools, a database for data handling, and a reporting feature. This is to ensure that the workflow of the application is optimized to ensure efficiency and high throughput in a clinical environment.

Device Characteristics

Single Use
No
Prescription Use (Rx)
No
Over the Counter (OTC)
No
Kit
No
Combination Product
No
HCT/P
No
Contains NRL
No
Not Made with NRL
No
MRI Safety
Labeling does not contain MRI Safety Information
Direct Marking Exempt
No
PM Exempt
No
Has Serial Number
No
Has Lot/Batch Number
Yes
Has Manufacturing Date
No
Has Expiration Date
No
Has Donation ID
No

Sterilization

Is Sterile
No
Sterilization Prior Use
No

Product Codes

Code Name
LLZ System, Image Processing, Radiological

GMDN Terms

Code Name
40872 MRI system application software

Identifiers

Type ID
Primary 07090042059015

Customer Contacts

Phone
+4755707095

Premarket Submissions

Submission Number Supplement Number
K163324 000