FDA UDI
In Commercial Distribution
🇺🇸 United States
Alligator grasper
DI: 06974880993155
·
Model: RSI-370-7-E
·
Suzhou AcuVu medical technology Co., Ltd.
Product Codes
1
GMDN Terms
1
Identifiers
3
Pkg Device Count
1
Basic Information
- Brand Name
- Alligator grasper
- Primary DI
- 06974880993155
- Version / Model
- RSI-370-7-E
- Company Name
- Suzhou AcuVu medical technology Co., Ltd.
- Labeler DUNS
- 705464292
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2025-05-08
- Public Version
- 1
- Public Version Date
- 2025-05-16
- Public Version Status
- New
- Public Device Record Key
- cd6954e9-e352-4870-abd3-1e4f1493c4c6
Device Description
The alligator grasper is intended to be used in hysteroscopy procedure for retrieval of foreign bodies and tissues from the uterine cavity.
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- No
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- Yes
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| HTD | Forceps | General, Plastic Surgery | 878.4800 | 1 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 35080 | Rigid endoscopic tissue manipulation forceps, reusable | A rigid, hand-held manual surgical instrument designed to be introduced through the working channel of an endoscope and/or an endoscopic port (e.g., laparoscopic port) primarily for grasping and manipulating tissues during endoscopic surgery. It has proximal controls (e.g., scissors-like handles), a rigid long slender shaft, and distal grasping jaws; it is not an electrosurgical device and is not dedicated to biopsy. This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Package | 16974880993152 | GS1 | 1 | In Commercial Distribution | ||
| Primary | 06974880993155 | GS1 | ||||
| Package | 26974880993159 | GS1 | 5 | In Commercial Distribution |
Customer Contacts
- Phone
- 6178344997
- [email protected]
Storage Conditions
- Type
- Handling Environment Temperature
- Temperature Range
- 10 – 45 Degrees Celsius
- Type
- Handling Environment Humidity
- Temperature Range
- 30 – 70 Percent (%) Relative Humidity
- Type
- Storage Environment Humidity
- Temperature Range
- 10 – 90 Percent (%) Relative Humidity
- Type
- Storage Environment Temperature
- Temperature Range
- -30 – 55 Degrees Celsius