FDA UDI
In Commercial Distribution
🇺🇸 United States
NA
DI: 06974599110003
·
Model: MGL-SP-6
·
Changsha Magill Medical Technology Co., Ltd.
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- NA
- Primary DI
- 06974599110003
- Version / Model
- MGL-SP-6
- Company Name
- Changsha Magill Medical Technology Co., Ltd.
- Labeler DUNS
- 703075567
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2021-10-29
- Public Version
- 3
- Public Version Date
- 2023-02-03
- Public Version Status
- Update
- Public Device Record Key
- fe44aa99-e4a8-47a1-95bc-ef8b877530f2
Device Description
Videoscope is a assistive device designed to operate in comination with Magill Medical's Disposable Video Laryngeal Mask to allow visualization during the processes of laryngeal mask insertion and post-insertion inspection and monitoring. This model is compatible with Magill Medical's #3, #4 and #5 laryngeal masks.
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- No
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- Yes
- Has Serial Number
- Yes
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- Yes
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| CAL | Laryngoscope, Non-Rigid | Anesthesiology | 868.5530 | 1 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 44962 | Flexible video intubation laryngoscope, reusable | An endoscope with a flexible inserted portion intended for the visual examination of the trachea, and to assist the entry and positioning of an airway tube, typically an endotracheal (ET) tube, to secure an open airway in the case of difficult and non-difficult intubation procedures. The inserted portion is thin and long to facilitate endoscope entry and the intubation procedure. Anatomical images are transmitted to the user by a video system with a charge-coupled device (CCD) chip at the distal end of the endoscope and the images showing on a monitor. It is typically used during difficult and non-difficult intubation procedures when maintaining an airway open. This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 06974599110003 | GS1 |