FDA UDI
Not in Commercial Distribution
🇺🇸 United States
Beamer AVEO™ Irrigation Pump
DI: 06946332803145
·
Model: AVEOPUMP
·
Chongqing Jinshan Science & Technology (Group) Co., Ltd
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Beamer AVEO™ Irrigation Pump
- Primary DI
- 06946332803145
- Version / Model
- AVEOPUMP
- Company Name
- Chongqing Jinshan Science & Technology (Group) Co., Ltd
- Labeler DUNS
- 545245755
- Distribution Status
- Not in Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2021-12-31
- Public Version
- 1
- Public Version Date
- 2022-01-10
- Public Version Status
- New
- Public Device Record Key
- 5219e063-276f-4a5e-9e1e-10bab5c6679a
- Distribution End Date
- 2022-01-03
Device Description
Endoscopic Irrigation Pump
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- Yes
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| OCX | Endoscopic Irrigation/Suction System | Gastroenterology, Urology | 876.1500 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 63646 | Surgical irrigation pump | An electrically-powered device, which may include noninvasive accessories, intended to pump a sterile fluid (e.g., saline water) to irrigate body cavities/wounds during surgery (e.g., general surgery, endoscopic). It is typically intended to be used to wash away tissues/fluids/debris with a sterile fluid to facilitate observation; it is not intended to administer parenteral fluids or drugs and is not capable of suction. The device may incorporate a display and may include collection containers or tubing; it does not include patient contact devices (e.g., handpiece/tip, catheter). | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 06946332803145 | GS1 |
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K210618 | 000 |