Basic Information
- Brand Name
- Contour+ (MVision AI Segmentation)
- Primary DI
- 06429830064206
- Version / Model
- 1.2
- Company Name
- Mvision AI Oy
- Labeler DUNS
- 368533510
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2024-12-31
- Public Version
- 1
- Public Version Date
- 2025-01-08
- Public Version Status
- New
- Public Device Record Key
- 5eecd037-8585-4468-b0dd-93736a4a4e89
Device Description
Contour+ (MVision AI Segmentation) provides a software interface to image analysis algorithms to be used in clinical workflows including, but not limited to, radiation therapy treatment planning workflows. The system includes processing tools for automatically contouring of imaging data of supported modalities CT and MRI using machine learning based algorithms. The produced segmentation templates for regions of interest are intended to be transferred to appropriate image visualization systems to be used as a template for a medical professional to visualize, modify and approve prior to further use in clinical workflows. The system supports automatic contouring of pre-defined structures from common anatomical sites, i.e. Head and Neck, Brain, Breast, Lung and Abdomen, Male Pelvis, and Female Pelvis. Contour+ (MVision AI Segmentation) is not intended to detect lesions or tumors. The device is not intended for use with real-time adaptive planning workflows.
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- Yes
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| QKB | Radiological Image Processing Software For Radiation Therapy | Radiology | 892.2050 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 47502 | Image segmentation application software | An application software program intended to convert large volumes of slice-based images into manageable three-dimensional (3-D) models of anatomical structures. It is typically used in an electrophysiology (EP) procedure (e.g., a cardiac mapping) to accept DICOM3 images from computed tomography (CT) and magnetic resonance imaging (MRI) scanners. Once the images are imported, a 3-D model can be extracted in a process called segmentation (the isolation of an object of interest) for easy viewing and manipulation during the EP procedure. This device is typically identified by a proprietary name and "version" or "upgrade" number. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 06429830064206 | GS1 |
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K241490 | 000 |