FDA UDI
In Commercial Distribution
🇺🇸 United States
VYAFUSER™
DI: 05713495001128
·
Model: VYAFUSER PUMP KIT US (R)
·
Phillips-Medisize A/S
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
1
Basic Information
- Brand Name
- VYAFUSER™
- Primary DI
- 05713495001128
- Version / Model
- VYAFUSER PUMP KIT US (R)
- Catalog Number
- 2089870410
- Company Name
- Phillips-Medisize A/S
- Labeler DUNS
- 306047440
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2025-09-03
- Public Version
- 1
- Public Version Date
- 2025-09-11
- Public Version Status
- New
- Public Device Record Key
- b7e0e7a2-1967-460f-9f5e-4e0a98d18489
Device Description
The VYAFUSER™ Pump is an ambulatory infusion pump intended for the subcutaneous delivery of VYALEV
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- Yes
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- MR Unsafe
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- Yes
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| FRN | Pump, Infusion | General Hospital | 880.5725 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 66485 | Ambulatory syringe pump | A battery-powered ambulatory device designed to precisely drive the plunger of a syringe down its barrel to infuse a solution when it must be administered with a high degree of volume accuracy and rate consistency; it is not dedicated to insulin infusion. Sometimes referred to as a portable syringe driver, it consists of a small unit with a syringe driving mechanism. It is used with a suitable injection/infusion set for delivery of small/finite volumes via an intravenous, subcutaneous, arterial, epidural or intracavital route. It is typically worn in a case attached to the belt or carried in a pocket and may be worn by the patient within and outside healthcare settings. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Direct Marking | 05713495001043 | GS1 | ||||
| Primary | 05713495001128 | GS1 |
Customer Contacts
- Phone
- (866) 489-2538
- [email protected]
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Length | 6.7 | Inch | |
| Width | 3 | Inch | |
| Depth | 1.3 | Inch | |
| Weight | 285 | Gram |
Storage Conditions
- Type
- Handling Environment Atmospheric Pressure
- Temperature Range
- 70 – 106 KiloPascal
- Type
- Storage Environment Atmospheric Pressure
- Temperature Range
- 53.3 – 106 KiloPascal
- Type
- Storage Environment Temperature
- Temperature Range
- -4 – 140 Degrees Fahrenheit
- Type
- Storage Environment Humidity
- Temperature Range
- 15 – 90 Percent (%) Relative Humidity
- Type
- Handling Environment Temperature
- Temperature Range
- 41 – 104 Degrees Fahrenheit
- Type
- Handling Environment Humidity
- Temperature Range
- 15 – 90 Percent (%) Relative Humidity