FDA UDI In Commercial Distribution 🇺🇸 United States

WAW HYBRID TORNADO PUNCH 1.00

DI: 05430003362150 · Model: 1.002508 · Devroye Instruments Belgium
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1

Basic Information

Brand Name
WAW HYBRID TORNADO PUNCH 1.00
Primary DI
05430003362150
Version / Model
1.002508
Company Name
Devroye Instruments Belgium
Labeler DUNS
372521769
Distribution Status
In Commercial Distribution
Device Count in Pkg
1
Record Status
Published
Publish Date
2025-05-09
Public Version
1
Public Version Date
2025-05-19
Public Version Status
New
Public Device Record Key
e2704c8d-747d-4ea1-995c-d96af776e1ca

Device Description

The WAW Hybrid Tornado Punch is a single use medical device intended to prepare follicular units for extraction from a patient's body, as part of a hair transplantation procedure. This is done by coring the tissues included in the hair follicle to separate them from the surrounding tissues. The movement of the WAW Hybrid Tornado Punch is intended to be provided by its accessory, the WAW Duo FUE System active device. The punch is intended to be used with the WAW Duo FUE System. More specifically, the punch is intended to be mounted on the handpiece of the system. It is inserted in the handpiece extremity during the FUE procedure. The punch is compatible with both handpieces of the system (wired and wireless). The device is invasive and sterilizable (autoclave), but not reusable. The device is intended to be sterilized by the user before use. A maximum of two devices can be used during a single procedure. The WAW Hybrid Tornado Punch is available in 8 different diameters ranging from 0.8 to 1.2 mm. The choice of punch depends on the number of hairs per graft, the thickness of the hairs and how close they are to each other. Additionally, the Hybrid Tornado Schambach Notches Punch is an extra model with 4 notches on the toothed part specifically designed for extracting long hair (Long Hair FUE). It comes in a single diameter of 1.0 mm, in two different materials (two different types of stainless steel).

Device Characteristics

Single Use
Yes
Prescription Use (Rx)
Yes
Over the Counter (OTC)
No
Kit
No
Combination Product
No
HCT/P
No
Contains NRL
No
Not Made with NRL
No
MRI Safety
Labeling does not contain MRI Safety Information
Direct Marking Exempt
No
PM Exempt
Yes
Has Serial Number
No
Has Lot/Batch Number
Yes
Has Manufacturing Date
Yes
Has Expiration Date
No
Has Donation ID
No

Sterilization

Is Sterile
No
Sterilization Prior Use
Yes
Sterilization Methods
Moist Heat or Steam Sterilization

Product Codes

Code Name
GEY Motor, Surgical Instrument, Ac-Powered

GMDN Terms

Code Name
35290 Hair extraction punch

Identifiers

Type ID
Primary 05430003362150

Customer Contacts

Phone
+3208807064

Device Sizes

Type Value Unit Text
Outer Diameter 1.00 Millimeter