FDA UDI
Not in Commercial Distribution
🇺🇸 United States
Current®
DI: 05414734501927
·
Model: DR RF
·
ST. JUDE MEDICAL, INC.
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
1
Basic Information
- Brand Name
- Current®
- Primary DI
- 05414734501927
- Version / Model
- DR RF
- Catalog Number
- 2207-36
- Company Name
- ST. JUDE MEDICAL, INC.
- Labeler DUNS
- 790268031
- Distribution Status
- Not in Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2017-01-24
- Public Version
- 5
- Public Version Date
- 2021-02-05
- Public Version Status
- Update
- Public Device Record Key
- 393516d3-c525-4601-8cd9-947df9697078
- Distribution End Date
- 2018-02-13
Device Description
Tiered-therapy cardioverter/defibrillator VVED DDDR
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- Yes
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- Yes
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| NVZ | Pulse generator, permanent, implantable | Unknown | 3 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 37265 | Dual-chamber implantable defibrillator | A battery-powered, hermetically-sealed pulse generator with a cardiac rhythm recognition system intended to collect and analyse electrocardiogram (ECG) data and deliver appropriate electrical impulses to defibrillate the heart (restore normal rhythm) or slow a rapid heart rate, and to pace the heart (to treat bradycardia). It is implanted in a pouch beneath the skin of the patient's chest or abdomen and intended to be used with leads that are positioned inside the right atrium and right ventricle to monitor the ECG and to automatically deliver the electrical impulse; it is commonly known as an automatic implantable cardioverter-defibrillator (AICD). | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 05414734501927 | GS1 | ||||
| Secondary | H7582207360 | HIBCC |
Customer Contacts
- Phone
- +1(855)478-5833
- [email protected]
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Total Volume | 42 | Milliliter |
Storage Conditions
- Type
- Handling Environment Temperature
- Temperature Range
- -20 – 60 Degrees Celsius
- Type
- Storage Environment Temperature
- Temperature Range
- 10 – 45 Degrees Celsius
- Type
- Storage Environment Temperature
- Temperature Range
- 50 – 113 Degrees Fahrenheit
- Type
- Special Storage Condition, Specify
- Special Conditions
- Store the device away from magnets and sources of electromagnetic interference.