FDA UDI
In Commercial Distribution
🇺🇸 United States
Tendril™
DI: 05414734501743
·
Model: ST
·
ST. JUDE MEDICAL, INC.
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Tendril™
- Primary DI
- 05414734501743
- Version / Model
- ST
- Catalog Number
- 1888TC-46
- Company Name
- ST. JUDE MEDICAL, INC.
- Labeler DUNS
- 790268031
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2017-02-03
- Public Version
- 4
- Public Version Date
- 2021-02-05
- Public Version Status
- Update
- Public Device Record Key
- f1e7fd0c-7330-4b99-9c7e-47af27aa935e
Device Description
Pacing Lead
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- Yes
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- Yes
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- Yes
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| NVY | Permanent defibrillator electrodes | Unknown | 3 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 35223 | Endocardial pacing lead | An implantable flexible wire with an electrode, insulated with non-conductive material except at its ends, which serves as an electrical conductor to transmit pacing impulses from an implanted pulse generator to the heart; it is not intended to conduct defibrillation impulses. It may also transmit electrical responses from the heart back to the pacemaker. The electrode end is normally placed through a vein to contact the wall of one of the heart's chambers (endocardium), and the other end is connected to the pacemaker. It is typically impregnated with a steroid (e.g., dexamethasone) intended to elute into the tissues to reduce inflammation. | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 05414734501743 | GS1 |
Customer Contacts
- Phone
- +1(855)478-5833
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| P960013 | 018 |
| P960013 | 083 |
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Length | 46 | Centimeter |
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- 23 – 122 Degrees Fahrenheit
- Type
- Handling Environment Temperature
- Temperature Range
- -5 – 50 Degrees Celsius
- Type
- Storage Environment Temperature
- Temperature Range
- -5 – 50 Degrees Celsius
- Type
- Handling Environment Temperature
- Temperature Range
- 23 – 122 Degrees Fahrenheit