FDA UDI In Commercial Distribution 🇺🇸 United States

FeNOBreath

DI: 05060246860320 · Model: FeNOBreath · BEDFONT SCIENTIFIC LIMITED
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1

Basic Information

Brand Name
FeNOBreath
Primary DI
05060246860320
Version / Model
FeNOBreath
Catalog Number
FENOBREATH-MGC
Company Name
BEDFONT SCIENTIFIC LIMITED
Labeler DUNS
293959094
Distribution Status
In Commercial Distribution
Device Count in Pkg
1
Record Status
Published
Publish Date
2022-01-06
Public Version
1
Public Version Date
2022-01-14
Public Version Status
New
Public Device Record Key
2eb0e3ef-2445-49fb-8258-2f006619b784

Device Description

The FeNObreath is a portable, non-invasive device for the measurement of Fractional Exhaled Nitric Oxide (FeNO) in human breath. The production of nitric oxide is often found to be increased in inflammatory conditions such as asthma. Measurement of FeNO by FeNObreath is a method to measure the decrease in FeNO concentration in asthma patients that often occurs after treatment with anti-inflammatory pharmacological therapy, as an indication of the therapeutic effect in patients with elevated FeNO levels. The fractional NO concentration in expired breath (FeNO), can be measured by FeNObreath according to guidelines for NO measurement established by the American Thoracic Society. FeNObreath is intended for children, 7- 17 years, and adults 18 years and older. FeNObreath 12 second test mode is for age 7 and up FeNObreath 10 second test mode is for ages 7-10 only who cannot successfully complete a 12 second test. FeNO measurements provide the physician with means of evaluating an asthma patient's response to anti-inflammatory therapy, as an adjunct to the established clinical and laboratory assessments in asthma. The FeNObreath cannot be used with infants or by children under the age of 7 as measurement requires patient cooperation. FeNObreath should not be used in critical care, emergency care or in anesthesiology.

Device Characteristics

Single Use
No
Prescription Use (Rx)
No
Over the Counter (OTC)
No
Kit
No
Combination Product
No
HCT/P
No
Contains NRL
No
Not Made with NRL
No
MRI Safety
Labeling does not contain MRI Safety Information
Direct Marking Exempt
No
PM Exempt
No
Has Serial Number
Yes
Has Lot/Batch Number
No
Has Manufacturing Date
Yes
Has Expiration Date
No
Has Donation ID
No

Sterilization

Is Sterile
No
Sterilization Prior Use
No

Product Codes

Code Name
MXA System, Test, Breath Nitric Oxide

GMDN Terms

Code Name
65453 Nitric oxide breath analyser

Identifiers

Type ID
Primary 05060246860320

Premarket Submissions

Submission Number Supplement Number
K203695 000