FDA UDI
In Commercial Distribution
🇺🇸 United States
SLK Evo
DI: 05051693400290
·
Model: CS Femoral (PS) Left 65mm
·
IMPLANTS INTERNATIONAL LTD
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- SLK Evo
- Primary DI
- 05051693400290
- Version / Model
- CS Femoral (PS) Left 65mm
- Catalog Number
- KS5988
- Company Name
- IMPLANTS INTERNATIONAL LTD
- Labeler DUNS
- 346627222
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-07-31
- Public Version
- 2
- Public Version Date
- 2018-03-29
- Public Version Status
- Update
- Public Device Record Key
- 57d75591-711b-4d51-92f8-de2a99d18b92
Device Description
Cruciate Sacrificing (Posterior Stabilised) Femoral Componant for Cemented applications (Cobalt Chrome), Denoted size 65mm (Width) Anatomical Orientation - Left
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- MR Conditional
- Direct Marking Exempt
- Yes
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| JWH | Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer | Orthopedic | 888.3560 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 33665 | Posterior-stabilized total knee prosthesis | A sterile implantable artificial substitute for a knee joint typically designed to replace all the articulating surfaces of the damaged/degenerative joint [total knee arthroplasty (TKA)] or for prosthesis revision; it is implanted when the posterior cruciate ligament is sacrificed and uses a “cam and post†mechanism to replace the stabilizing function of the ligament. It includes femoral, tibial, and patellar components that articulate and with parts made of metal, ceramic, and/or polyethylene (PE); it may be implanted with or without bone cement and is often used in cases where bone stock and mediolateral stability are good in the face of severe deformities or ligament degeneration. | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 05051693400290 | GS1 |
Customer Contacts
- Phone
- +4401642769080
- [email protected]
- Phone
- +4401642769080
- [email protected]
- Phone
- +4401642769080
- [email protected]
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Width | 65 | Millimeter |
Storage Conditions
- Type
- Special Storage Condition, Specify
- Special Conditions
- Room temperature and Dry