OPTICAL COHERENCE TOMOGRAPHY
Let the assistant research this device
The Research Assistant compiles product codes, classification, clearances and adverse events for this device — and cites every record.
Free to try · every answer cites its records
Basic Information
- Brand Name
- OPTICAL COHERENCE TOMOGRAPHY
- Primary DI
- 04987669100516
- Version / Model
- RS-3000 Advance
- Company Name
- NIDEK CO.,LTD.
- Labeler DUNS
- 690635461
- Distribution Status
- Not in Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-06-24
- Public Version
- 3
- Public Version Date
- 2026-04-10
- Public Version Status
- Update
- Public Device Record Key
- 05425139-b4c7-436b-8370-5d720a8aa846
- Distribution End Date
- 2025-12-22
Device Description
The NIDEK Optical Coherence Tomography RS-3000 Advance is an ophthalmic camera that allows non-invasive and non-contact observation of the shape of the fundus or retina. Fundus surface images (hereafter referred to as SLO image) are captured with the confocal laser scanning using a near-infrared light source with a wavelength of 785 nm. Cross-sectional images of the retina (hereafter referred to as OCT image) are captured with the optical interferometer using an infrared light source with a wavelength of 880 nm. With the images captured using the RS-3000 Advance, the shape and structure of the fundus or retina can be observed, and diseases can be observed. This system is comprised of the main body for capturing images, a computer (hereafter called PC) for storing and analyzing captured images, PC monitor, and an isolation transformer. In addition, the image filing software NAVIS-EX (hereafter referred to as NAVIS-EX) offers the following features: • Image analysis functions such as 3D/map color display or retinal thickness analysis • Networking for data review or analysis on PCs in separate locations
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- Yes
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| OBO | Tomography, Optical Coherence | Ophthalmic | 886.1570 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 64004 | Scanning-laser ophthalmoscope/retinal optical coherence tomography system | An ophthalmic digital image capturing/processing device that is a combination of a scanning-laser ophthalmic imaging system and a retinal optical coherence tomography system intended to: 1) use a low power laser to generate and capture digital confocal images, 2) use a broad-bandwidth light beam aimed into the eye for in vivo tomographic imaging and measurement, of the retina and associated structures to diagnose and manage retinal diseases. It typically consists of a laser, optics, image detection system, a digital processor/computer, application software and image display monitor(s). | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 04987669100516 | GS1 |
Customer Contacts
- Phone
- 1-800-223-9044
- [email protected]