FDA UDI
In Commercial Distribution
🇺🇸 United States
ENDOSCOPE POSITION MARKING PROBE
DI: 04953170353406
·
Model: MAJ-1878
·
OLYMPUS MEDICAL SYSTEMS CORP.
Product Codes
3
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- ENDOSCOPE POSITION MARKING PROBE
- Primary DI
- 04953170353406
- Version / Model
- MAJ-1878
- Company Name
- OLYMPUS MEDICAL SYSTEMS CORP.
- Labeler DUNS
- 711789789
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-09-21
- Public Version
- 6
- Public Version Date
- 2023-01-16
- Public Version Status
- Update
- Public Device Record Key
- a2e21c8e-5fa7-4363-94ea-7756fe27e14c
Device Description
MAJ-1878 SCOPEGUIDE PROBE 2.8MM
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- Yes
- PM Exempt
- No
- Has Serial Number
- Yes
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- ["High-level Disinfectant", "Ethylene Oxide"]
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| PGU | Spatial imaging for display of endoscope position | Gastroenterology, Urology | 876.1500 | 2 |
| FDA | Enteroscope and accessories | Gastroenterology, Urology | 876.1500 | 2 |
| FDF | Colonoscope and accessories, flexible/rigid | Gastroenterology, Urology | 876.1500 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 64659 | Electromagnetic endoscope tracking system reference transmitter, internal | A long, flexible, invasive component of an electromagnetic (EM) endoscope tracking system intended for insertion into one of the channels (e.g., biopsy channel) of an appropriate in situ endoscope, and designed to emit EM pulses for locating/tracking the endoscope. It is intended to be used with endoscopes which do not have integrated EM pulse-generating tracking technology. The EM field/pulses generated by this device are received by external sensors. This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 04953170353406 | GS1 |
Customer Contacts
- Phone
- +1(800)401-1086
- [email protected]