FDA UDI
Not in Commercial Distribution
🇺🇸 United States
EVIS EXERA II COLONOVIDEOSCOPE
DI: 04953170237300
·
Model: OLYMPUS PCF TYPE H180AI
·
OLYMPUS MEDICAL SYSTEMS CORP.
Product Codes
3
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- EVIS EXERA II COLONOVIDEOSCOPE
- Primary DI
- 04953170237300
- Version / Model
- OLYMPUS PCF TYPE H180AI
- Company Name
- OLYMPUS MEDICAL SYSTEMS CORP.
- Labeler DUNS
- 711789789
- Distribution Status
- Not in Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-09-21
- Public Version
- 6
- Public Version Date
- 2024-01-15
- Public Version Status
- Update
- Public Device Record Key
- e8288a0b-3415-4c3e-9f43-873a2d0fc413
- Distribution End Date
- 2024-01-12
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- Yes
- PM Exempt
- No
- Has Serial Number
- Yes
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- ["Ethylene Oxide", "High-level Disinfectant"]
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| FDF | Colonoscope and accessories, flexible/rigid | Gastroenterology, Urology | 876.1500 | 2 |
| FDS | Gastroscope and accessories, flexible/rigid | Gastroenterology, Urology | 876.1500 | 2 |
| NWB | Endoscope, accessories, narrow band spectrum | Gastroenterology, Urology | 876.1500 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 36117 | Flexible video colonoscope, reusable | An endoscope with a flexible inserted portion intended for the visual examination and treatment of the entire colon [lower gastrointestinal (GI) tract]. It is inserted through the anus during colonoscopy. Anatomical images are transmitted to a monitor for viewing by a video system with a charge-coupled device (CCD) chip at the distal end of the endoscope. This device is commonly used to examine the lining of the colon or to evaluate altered bowel habits, colonic cancer, polyps, diverticular disease, occult or frank blood in stools, or unexplained anaemia. This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 04953170237300 | GS1 |
Customer Contacts
- Phone
- +1(800)401-1086
- [email protected]