NISSEI
Basic Information
- Brand Name
- NISSEI
- Primary DI
- 04931140011334
- Version / Model
- DSK-1011
- Company Name
- NIHON SEIMITSU SOKKI CO., LTD.
- Labeler DUNS
- 690593702
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-09-16
- Public Version
- 3
- Public Version Date
- 2019-11-08
- Public Version Status
- Update
- Public Device Record Key
- 64321446-83a0-43b4-8d76-d4f1f902ad76
Device Description
DSK-1011 is an upper arm type blood pressure monitor. This product is intended for noninvasive measurement of systolic and diastolic blood pressure and pulse rate as well as calculation of pulse pressure in adults in a home healthcare environment. The product is not designed for neonatal use. Measurement is performed during the inflation of the cuff. The cuff is automatically inflated rapidly at the initial phase then gradually afterwards. The masurement ends as the systolic blood pressure is determined and then the measurement result is displayed. The initial rapid inflation value is set by the readings of the last three measurements by the function so-called Personal Mode. Other functions such as WHO Classification indication, Pulse Pressure display, Body Motion indicator, and Irregular Pulse Rhythm indicatcion are equipped. Up to 60 readings in 2 memory banks can be stored.
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- No
- Over the Counter (OTC)
- Yes
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- Yes
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| DXN | System, Measurement, Blood-Pressure, Non-Invasive | Cardiovascular | 870.1130 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 16173 | Automatic-inflation electronic sphygmomanometer, non-portable | An electrically-powered device designed to noninvasively measure blood pressure using a self-contained software program that regulates automatic arm-cuff inflation and measurement cycles. It typically displays current heart rate and mean arterial pressure in addition to systolic and diastolic blood pressures; it may have memory to store blood pressure values and may sound an alarm if blood pressure exceeds pre-set limits. This device is not designed to be portable and is typically used bedside. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 04931140011334 | GS1 | ||||
| Package | 14931140011331 | GS1 | master carton | 20 | In Commercial Distribution |
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Depth | 2.6 | Inch | |
| Height | 4.5 | Inch | |
| Width | 4.5 | Inch |
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- -4 – 131 Degrees Fahrenheit
- Type
- Storage Environment Humidity
- Temperature Range
- 0 – 90 Percent (%) Relative Humidity
- Type
- Handling Environment Temperature
- Temperature Range
- 50 – 104 Degrees Fahrenheit
- Type
- Handling Environment Humidity
- Temperature Range
- 15 – 90 Percent (%) Relative Humidity