FDA UDI
In Commercial Distribution
🇺🇸 United States
Microware Bone Plates and Bone Screws
DI: 04719872227908
·
Model: 209630G-000
·
MICROWARE PRECISION CO., LTD.
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Microware Bone Plates and Bone Screws
- Primary DI
- 04719872227908
- Version / Model
- 209630G-000
- Company Name
- MICROWARE PRECISION CO., LTD.
- Labeler DUNS
- 658650833
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-04-07
- Public Version
- 4
- Public Version Date
- 2024-02-19
- Public Version Status
- Update
- Public Device Record Key
- 60b42ae5-76c6-490d-bee9-0b4fdd7ec003
Device Description
CANNULATED SCREW 7.3mm x 30mm, FULLY THREADED, HEXAGON SOCKET
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| HWC | Screw, Fixation, Bone | Orthopedic | 888.3040 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 61689 | Internal orthopaedic fixation system, plate/screw, non-bioabsorbable, non-sterile | A non-sterile assembly of implantable devices designed for the stabilization of fractured/surgically-cut bones of the limbs (long bones), their appendages (hands, feet), pelvis, craniomaxillofacial bones, and/or for limb-joint fusion. It typically consists of a set of bone fixation plates, screws, wires, and pins made of materials that cannot be chemically degraded or absorbed via natural body processes (e.g., implant grade metal, surgical steel, titanium alloy, or carbon fibre). It may also include instruments for the attachment of the implants such as screwdrivers or drills. This device is intended to be sterilized prior to use. | No | Obsolete |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 04719872227908 | GS1 |
Customer Contacts
- Phone
- +886424636275
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K111008 | 000 |