FDA UDI
In Commercial Distribution
🇺🇸 United States
U2 Acetabular Components, XPE Cup Liner
DI: 04712771483741
·
Model: 1403-1064
·
UNITED ORTHOPEDIC CORP.
Product Codes
2
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- U2 Acetabular Components, XPE Cup Liner
- Primary DI
- 04712771483741
- Version / Model
- 1403-1064
- Catalog Number
- 1403-1064
- Company Name
- UNITED ORTHOPEDIC CORP.
- Labeler DUNS
- 656700556
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2015-10-24
- Public Version
- 4
- Public Version Date
- 2018-08-06
- Public Version Status
- Update
- Public Device Record Key
- 7a00dc74-baca-4775-990d-043e19dc29f1
Device Description
XPE Cup Liner, ID 28 mm, 10°× 64mm
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| LPH | Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented | Orthopedic | 888.3358 | 2 |
| JDI | Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented | Orthopedic | 888.3350 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 33181 | Metal-on-polyethylene total hip prosthesis | A sterile implantable artificial substitute for a diseased (e.g., arthritic) or injured hip joint consisting of matching femoral (head/shaft) and acetabular components articulated at a metal-on-polyethylene or cross-linked polyethylene interface. Fixation devices for implantation (e.g., screws and bolts) may be included and implantation may be performed with or without bone cement. | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 04712771483741 | GS1 |
Customer Contacts
- Phone
- +886229294567
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K111546 | 000 |
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Angle | 10 | degree | |
| Lumen/Inner Diameter | 28 | Millimeter | |
| Outer Diameter | 64 | Millimeter |