FDA UDI
In Commercial Distribution
🇺🇸 United States
Conformity Stem
DI: 04711605586573
·
Model: 9110-5010
·
UNITED ORTHOPEDIC CORP.
Product Codes
4
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Conformity Stem
- Primary DI
- 04711605586573
- Version / Model
- 9110-5010
- Catalog Number
- 9110-5010
- Company Name
- UNITED ORTHOPEDIC CORP.
- Labeler DUNS
- 656700556
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2019-09-02
- Public Version
- 2
- Public Version Date
- 2020-01-09
- Public Version Status
- Update
- Public Device Record Key
- c02af743-abf7-4e0c-b970-f5ba4770ff6e
Device Description
Neck trial, STD, 135°
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| MEH | Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate | Orthopedic | 888.3353 | 2 |
| LZO | Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented | Orthopedic | 888.3353 | 2 |
| KWY | Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented | Orthopedic | 888.3390 | 2 |
| JDI | Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented | Orthopedic | 888.3350 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 58481 | Femoral stem prosthesis trial | A copy of a final femoral stem prosthesis designed to be used for trial reductions during hip arthroplasty to judge the correct offset, leg-length, and range of motion of the final femoral prosthesis to be implanted. It is one of a set, or a set, of graduated sizes, and is used in conjunction with femoral head trial prostheses. It is typically made of metal or polymer material and includes trial stems, trial sleeves, and trial necks. This is a reusable device intended to be sterilized prior to use. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 04711605586573 | GS1 |
Customer Contacts
- Phone
- +886 0229294567
- [email protected]