FDA UDI
In Commercial Distribution
🇺🇸 United States
CryotopCL(G)
DI: 04582231461950
·
Model: CryotopCL(G)
·
KITAZATO CORPORATION
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
1
Basic Information
- Brand Name
- CryotopCL(G)
- Primary DI
- 04582231461950
- Version / Model
- CryotopCL(G)
- Company Name
- KITAZATO CORPORATION
- Labeler DUNS
- 711091157
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-11-08
- Public Version
- 3
- Public Version Date
- 2023-05-31
- Public Version Status
- Update
- Public Device Record Key
- 8480be33-7728-409e-8d12-e1250c3160fe
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- No
- Over the Counter (OTC)
- Yes
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- Yes
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- Yes
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| MQK | LABWARE, ASSISTED REPRODUCTION | Obstetrics/Gynecology | 884.6160 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 47446 | Assisted reproduction vitrification carrier | A sterile, plastic device used during an assisted reproduction vitrification (cryopreservation) procedure to hold a small volume of vitrification media containing a biological specimen (e.g., egg, embryo) to vitrify (cryopreserve) the specimen, thereby avoiding specimen immersion/contact with LN2. The vitrification process may involve the distal tip/specimen being brought into contact with the surface of a vitrification block [a highly-conductive mass of metal semi-submersed in a liquid nitrogen (LN2) bath]. The device with vitrified specimen is then stored in an LN2 tank, and subsequently transferred into a warming medium to recover the specimen. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Package | 14582231461957 | GS1 | 10 | In Commercial Distribution | ||
| Primary | 04582231461950 | GS1 |
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- 15 – 30 Degrees Celsius