FDA UDI
In Commercial Distribution
🇺🇸 United States
FUJIFILM
DI: 04547410331035
·
Model: EG-530NP
·
FUJIFILM CORPORATION
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
1
Basic Information
- Brand Name
- FUJIFILM
- Primary DI
- 04547410331035
- Version / Model
- EG-530NP
- Company Name
- FUJIFILM CORPORATION
- Labeler DUNS
- 713565195
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-12-14
- Public Version
- 2
- Public Version Date
- 2018-03-29
- Public Version Status
- Update
- Public Device Record Key
- bfcc8dd5-b90f-45fa-a4be-885e5ac9d0bc
Device Description
The device is intended for the visualization of upper digestive tract, specifically for the observation, diagnosis, and endoscopic treatment of the esophagus, stomach, and duodenal bulb. The device can be inserted orally or trans nasally.
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- No
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- Yes
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- ["High-level Disinfectant", "Ethylene Oxide"]
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| FDS | Gastroscope and accessories, flexible/rigid | Gastroenterology, Urology | 876.1500 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 38805 | Flexible video gastroduodenoscope | An endoscope with a flexible inserted portion intended for the visual examination and treatment of the upper gastrointestinal (GI) tract [oesophagus, stomach, and duodenum (the first part of the small intestine), including the pancreas and the bile duct]. It is inserted into the body through the mouth during gastroduodenoscopy. Anatomical images are transmitted to the user by a video system with a charge-coupled device (CCD) chip at the distal end of the endoscope and the images showing on a monitor. It can be end-viewing (looking forward) or side-viewing (looking to one side) and is used for the cannulation of the pancreas and bile duct. This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 04547410331035 | GS1 | ||||
| Package | 14547410331032 | GS1 | Box | 1 | In Commercial Distribution |
Customer Contacts
- Phone
- +018002728465
- [email protected]
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- 10 – 40 Degrees Celsius
- Type
- Handling Environment Humidity
- Temperature Range
- 30 – 85 Percent (%) Relative Humidity
- Type
- Handling Environment Atmospheric Pressure
- Temperature Range
- 70 – 106 KiloPascal
- Type
- Storage Environment Atmospheric Pressure
- Temperature Range
- 70 – 106 KiloPascal
- Type
- Handling Environment Temperature
- Temperature Range
- 10 – 40 Degrees Celsius
- Type
- Storage Environment Humidity
- Temperature Range
- 30 – 85 Percent (%) Relative Humidity
- Type
- Special Storage Condition, Specify
- Special Conditions
- There must be no condensation.