FDA UDI
In Commercial Distribution
🇺🇸 United States
Liposat basic infiltration pump
DI: 04260277173920
·
Model: 00002498
·
Möller Medical GmbH
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Liposat basic infiltration pump
- Primary DI
- 04260277173920
- Version / Model
- 00002498
- Company Name
- Möller Medical GmbH
- Labeler DUNS
- 320405061
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-09-24
- Public Version
- 3
- Public Version Date
- 2018-08-23
- Public Version Status
- Update
- Public Device Record Key
- 377e9d6d-822c-4f0a-8504-d56403a86907
Device Description
The tumescence pump “Liposat basic” serves to convey sterile saline solution into human tissue through a tubing system with an insertion canula. The tumescence pump “Liposat basic” may only be operated in connection with the tubing set „Tubing set for tumescence pump Liposat basic“ REF: 00002492 by Möller Medical.
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- No
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- Yes
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| MUU | System, Suction, Lipoplasty | General, Plastic Surgery | 878.5040 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 36894 | Liposuction system | An assembly of devices designed specifically to aspirate subcutaneous fat from the body by means of suction during a liposuction/lipectomy procedure. The system consists of an electrically-powered suction pump, typically with collection containers, tubing, and microbial/hydrophobic filters, and includes patient contact devices (e.g., handpiece/tip, cannula). The pump generates negative pressure for aspiration of fat through the patient contact device, which is inserted subcutaneously into the fat layer, and into the collection containers. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 04260277173920 | GS1 |