Sentiero Desktop Diagnostic
Basic Information
- Brand Name
- Sentiero Desktop Diagnostic
- Primary DI
- 04260223141584
- Version / Model
- 100497-US13
- Company Name
- PATH medical GmbH
- Labeler DUNS
- 551540334
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2018-03-31
- Public Version
- 7
- Public Version Date
- 2022-09-29
- Public Version Status
- Update
- Public Device Record Key
- 838717b3-aa07-45fb-8abe-f9169b2a174b
Device Description
Sentiero Desktop Screening TY / Diagnostic Set US13 Content: 1. Carton for Sentiero Desktop AN100728 2. Sentiero Desktop (Tymp Diagnostic) AN100434-DG 3. USB data cable AN100418 4. Probe EP-TY long AN100188-US 5. Headphone DD-45 AN100306 6. FW Screening Tymp class 2 AN100560 7. FW Pure Tone Audiometer Class 3 AN100114 8. Bone conductor B81 AN100888 or B71W AN100344 optionally 9. Patient response button AN100171 10. DPOAE Software AN100110 11. TEOAE Software AN100109 12. DPHiRES Software AN100537 13. FMDPOAE Software AN100536 14. PC based Patient Management, Mira Software AN100116 15. Software label printer AN100414 16. Accessory box for Tymp probe AN100587 17. Accessory box AB08 AN100734-P 18. Power supply Senti / Sentiero Desktop FW7662M AN100524 or FW8002.1M AN101360 optionally 19. Power supply adapter Senti / Sentiero Desktop USA/-UK/-EU/-AUS AN100525-USA/-UK/-EU/-AUS or AN101251-USA/-UK/-EU/-AUS optionally 20. Test cavity tymp AN100549
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- Yes
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- Yes
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| EWO | Audiometer | Ear, Nose, Throat | 874.1050 | 2 |
| GWJ | Stimulator, Auditory, Evoked Response | Neurology | 882.1900 | 2 |
| ETY | Tester, Auditory Impedance | Ear, Nose, Throat | 874.1090 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 35747 | Evoked-potential audiometer | An electroacoustic instrument designed to evaluate the activity of the auditory pathway of the brain in response to an acoustic signal [auditory brainstem response (ABR)] it provides at the ear (e.g., clicks delivered through an earphone), without need of patient cooperation. The signal, detected via the device's scalp electrodes and possibly a reference electrode on the ear lobe, is measured using computer averaging and signal processing techniques. This device is typically used to assess the function of the auditory pathways and to differentiate coma due to metabolic factors from structural damage. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 04260223141584 | GS1 |
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K133012 | 000 |