FDA UDI
In Commercial Distribution
🇺🇸 United States
Accessory Box AB02
DI: 04260223140723
·
Model: 100207
·
PATH medical GmbH
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Accessory Box AB02
- Primary DI
- 04260223140723
- Version / Model
- 100207
- Company Name
- PATH medical GmbH
- Labeler DUNS
- 551540334
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2017-06-02
- Public Version
- 2
- Public Version Date
- 2018-03-29
- Public Version Status
- Update
- Public Device Record Key
- a3b82a09-aa36-487c-bdc1-47d1e989096b
Device Description
Accessory set including: 1 pc. 100013 Probe Tip PT-A 1 pc. 100219 Test Cavity for PT-A 5pcs. 100063 Ear Tip ET-03 5pcs. 100064 Ear Tip ET-10 5pcs. 100125 Ear Tip ET-11 5pcs. 100126 Ear Tip Soft ET-12 5pcs. 100144 Ear Tip ET-13 3pcs. 100230 Ear Tip Soft ET-14 1pc 100151 Cleaning Tool CT-01
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- Yes
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| GWJ | Stimulator, Auditory, Evoked Response | Neurology | 882.1900 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 35747 | Evoked-potential audiometer | An electroacoustic instrument designed to evaluate the activity of the auditory pathway of the brain in response to an acoustic signal [auditory brainstem response (ABR)] it provides at the ear (e.g., clicks delivered through an earphone), without need of patient cooperation. The signal, detected via the device's scalp electrodes and possibly a reference electrode on the ear lobe, is measured using computer averaging and signal processing techniques. This device is typically used to assess the function of the auditory pathways and to differentiate coma due to metabolic factors from structural damage. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 04260223140723 | GS1 |