FDA UDI
In Commercial Distribution
🇺🇸 United States
remOVE FBR Set
DI: 04260206310785
·
Model: 12
·
Ovesco Endoscopy AG
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
1
Basic Information
- Brand Name
- remOVE FBR Set
- Primary DI
- 04260206310785
- Version / Model
- 12
- Catalog Number
- 400.05
- Company Name
- Ovesco Endoscopy AG
- Labeler DUNS
- 344007369
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2018-10-02
- Public Version
- 3
- Public Version Date
- 2019-10-31
- Public Version Status
- Update
- Public Device Record Key
- ad673a45-404d-428a-9233-0e95e3faa4ff
Device Description
The remOVE FBR Set is a foreign body retrieval set for flexible endoscopy • safe removal of ingested foreign objects • it consists of the following products: remOVE SecureCap 12 (elastic and transparent retrieval cap) • remOVE Grasper (specially designed grasping forceps | alligator and rat teeth for strong hold and easy retrieval of foreign bodies into the remOVE Secure Cap)
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- Yes
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- Yes
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| KOA | Surgical Instruments, G-U, Manual (And Accessories) | Gastroenterology, Urology | 876.4730 | 1 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 33199 | Flexible endoscopic tissue manipulation forceps, single-use | A flexible, hand-held manual surgical instrument designed to be introduced through the working channel of an endoscope to grasp tissue (typically atraumatically), or additionally foreign bodies. It has proximal controls (e.g., scissors-like handles), a flexible long slender shaft, and distal grasping jaws; it is not an electrosurgical device and is not dedicated to biopsy. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Package | 04260206310778 | GS1 | folding box | 2 | In Commercial Distribution | |
| Primary | 04260206310785 | GS1 |
Customer Contacts
- Phone
- +49707196528160
- [email protected]
- Phone
- +19196519449
- [email protected]
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Device Size Text, specify | for endoscope diameter 9.5 - 12 mm | ||
| Device Size Text, specify | working channel diameter 2.8 mm | ||
| Device Size Text, specify | working length 220 cm |